Configuring Ethernet Services
117344-A Rev. A 2-7
The BofL Timeout interval is 5 seconds by default. You can change the interval of
BofL messages to a value from 1 to 60 seconds.
Using the BCC
To change the interval of BofL messages on an Ethernet interface, access an
existing Ethernet line service and enter:
bofl-timeout
<integer>
<integer>
is the timeout value expressed in seconds. You can enter any integer
value between 1 and 60.
For example, to set the timeout value to 10 seconds:
box> ethernet slot 13 connector 1
ethernet/13/1> bofl-timeout 10
Using Site Manager
Complete the tasks in the following table to change the interval of BofL messages.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose an XCVR Connector.
The Edit Connector window opens.
2. Choose Edit Line. The Edit CSMA/CD Parameters window
opens.
3. Set the BofL Timeout parameter. Click on
Help or see the parameter description on
page A-2.
4. Click on OK. Site Manager returns you to the Edit
Connector window.
5. Click on Done. Site Manager returns you to the
Configuration Manager window.
Note: In Site Manager, the BofL Timeout parameter is valid only if you set
BofL Enable to Enable.