BCC show Commands
308623-14.00 Rev 00
B-27
Command Timeouts Number of times a command timeout caused the interface to
reinitialize.
Host Interface Errors Number of times a receive-host interface error caused the interface
to reinitialize.
Line Errors
Slot/Conn Slot location of the token ring module within the chassis and the
connector number.
ARI/FCI Errors Number of times that this station received both an AMP MAC frame
and an SMP MAC frame with the a and c bits clear, or more than
one SMP MAC frame with the a and c bits clear without an
intervening AMP MAC frame. This condition indicates that the
upstream neighbor is unable to set the a and c bits in a frame that it
copied.
Frame Copied Errors Number of frames addressed to this station that had their a and c
bits previously set.
Token Errors Number of token protocol errors; relevant only when this station is
the active monitor.
Soft Errors Number of soft errors; corresponds to the number of Report Error
MAC frames that this station has transmitted.
Ring Errors
Slot/Conn Slot location of the token ring module within the chassis and the
connector number.
Beacon Events Number of events causing the adapter to transmit beacon frames.
Beacon frames indicate that the interface does not see the token. If
this count goes up, contact your Bay Networks Technical Solutions
Center.
Signal Losses Number of ring signal losses detected.
Auto Removes Number of times lobe wrap tests failed during beacon autoremoval.
Removes Received Number of Remove Ring Station MAC frames received. Each frame
causes this station to leave the ring.
Single Stations Number of interrupts caused by a change to the ring status while the
adapter is the only station on the ring.
Cable Faults Number of interrupts caused by opens or shorts (cable faults)
between the adapter and the MAU.
Ring Recoveries Number of Claim Token MAC frames (ring recoveries) observed on
the ring.