BayRS, BCC, and Site Manager Software Version 15.1.0.0 Fixed Anomalies
12
308681-15.1 Rev 00
CR Q00086321-02: NAT
When you configure a Static NAT entry, the router creates an erroneous 24-bit
masked network in the routing table. This may cause routing problems if a
routing protocol, such as RIP, is also configured in the network.
CR Q00089161-01: Hot Standby
In a configuration where a frame relay circuit is backed up by hot standby PPP
circuits, a bus error may occur when the sync interface bounces.
CR Q00089566-01: Web Server
Using the resource summary option of the HTTP Web Server, the CPU field
displays the message
data type mismatch
instead of the actual CPU statistics.
CR Q00091212-01: V34 modem
When you use the ARN V.34 internal modem to access the Technician Interface, a
failure may occur if you gracefully logged out of the previous dial console session
instead of disconnecting the modem via the dial application.
CR Q00092736-01: DLSw
When using a DLSw filter to route NetBEUI traffic over a Frame Relay circuit,
the router logs the message
Unexpected protocol action
when multiple
NetBEUI explorer frames are received.
CR Q00094625: TFTP
Although TFTP appears to be loaded on the router, it may fail to initialize if the
router tries to register with IP before the IP process is up.
CR Q00103159: RADIUS
When you enable the user/manager lock, and a RADIUS server is unavailable for
authentication, the router automatically disables the user/manager lock. However,
when the RADIUS server becomes available, the router does not automatically
enable the user/manager lock.