BayRS, BCC, and Site Manager Software Version 15.1.0.0 Fixed Anomalies
10
308681-15.1 Rev 00
CR Q00072335-01: ATMARP
When you are running ATMARP, duplicate virtual circuits show up for the same
NTP-enabled AIX server.
CR Q00075281-01: IPSec
While tunnels are being formed between a Passport 2430 and a CES 4500, a
collision occasionally occurs during the IKE negotiation of the ESP SAs because
BayRS and the switch don't agree on the latest inbound and outbound SAs.
CR Q00075297: RADIUS
A fault may occur during RADIUS UDP registration failure.
CR Q00075513-01: IPEX
When you are using an IPEX with multiple PVCs-to-TCP or TCP-to-PVC
gateway mappings, a fault on the router occurs if the logical channel numbers
(LCNs) of the PVCs are not consecutive.
CR Q00075870: DLSw
When in a redundant path environment, a DLSw connection may be left in an
inconsistent connected state after the router attempts and fails to make a
connection.
CR Q00079108-01: OSPF
When summarizing multiple subnetted networks, OSPF does not always advertise
the correct cost of the path in the area range summary update.
CR Q00080482-01: MOSPF
When you run unnumbered IP over PPP, MOSPF will be unable to generate
downstream interfaces.
CR Q00080547-01: Passport 2430
The Xircom PCMCIA modem version RM 56 V1.1 does not work in the
Passport 2430.