Troubleshooting your Enterprise Edge system 313
P0911588 Issue 01 Enterprise Edge 2.0 Programming Operations Guide
2. Enable the module using the procedure, Enable a module on page 280.
Follow the procedures in the Basic troubleshooting procedure on page 306 before
proceeding.
Auto-answer line rings at a telephone
The problem may be due to one of the following:
• Installed hardware does not support disconnect supervision on page 313
• Line is configured as auto-answer and unsupervised on page 313
• Line is not equipped for disconnect supervision at the central office on page 313
• Trunk module’s disconnect timer setting is not correct on page 314
Installed hardware does not support disconnect supervision
You configured a loop start trunk as auto-answer but the installed hardware does
not support disconnect supervision. (In this case, the symptom would be
accompanied by the Alarm 62 code symptom.) If the installed hardware does not
support disconnect supervision, reconfigure the trunk as manual-answer.
Line is configured as auto-answer and unsupervised
If the line is configured as auto-answer, reconfigure it as manual-answer. If the line
is configured as unsupervised, reconfigure it as supervised. Use the following
procedure.
1. Choose Services, Telephony Services, Lines.
2. Select the affected line.
3. Select Trunk/line data.
4. In the Trunk mode field, reconfigure the line as supervised by selecting
Super from the drop-down menu.
OR
In the Auto answer field, reconfigure the line as manual answer by selecting
Manual form the drop-down menu.
Line is not equipped for disconnect supervision at the central office
If the line is not equipped for disconnect supervision at the central office,
reconfigure the trunk as manual-answer using the following procedure:
1. Choose Services, Telephony Services, Lines.
2. Select the affected line.