60 Chapter 5 R2MFC MBM maintenance
N0027684 01
Table 11 shows the reactions for Group II alarms when they persist.
Faceplate LEDs
There are two sets of LEDs on the faceplate of the R2MFC MBM. The system status LEDs are
made up of the Power LED, In Service LED, and Diag LED. Table 12 shows the LEDs and their
states.
• As the BCM starts, the In Service LED is Green Flashing.
• Once powered up, the Power LED is set to Green, the In Service LED is set to green, and the
Diag LED is off.
• When the MBM is operating properly, the In Service LED is Green Solid.
• During an alarm on the internal PRI link, the In Service LED is off.
• During test mode, the Diag LED is red.
CRC-4 errors RAI AIS
FEBE none none
Table 11 Group II alarms propagation
Error Condition Alarm Transmitted to far-end Alarm sent on opposite link
LOS RAI AIS
AIS RAI AIS
OOF RAI AIS
OOM
TS16
RAI
TS16
AIS
AIS
TS16
RAI
TS16
AIS
RAI None RAI
RAI
TS16
None RAI
TS16
DCH down None AIS
Table 12 System status monitor LEDs
LED Status
LED Name Green Solid Green Flashing Red Solid Red Flashing OFF
Power
Active Power N/A N/A N/A No Power
In-Service
Normal Operation Start Up N/A N/A Out-of-Service
Diag
N/A N/A Test Mode N/A Normal Operation
Table 10 Group I Alarms propagation (Sheet 2 of 2)
Error Condition Alarm Transmitted to far end Alarm sent on opposite link