Station Port/Centrex Connections (cont'd)
Important Centrex Settings
Some phone systems (in particular, Centrex-type systems) may produce open-
switch-intervals (OSIs) when the UPAM first answers the line. OSIs are short
breaks in loop current resulting when the central office switches equipment on and
off the line. The UPAM may misinterpret these OSIs as disconnect signals. It may
be necessary to set AUX switch bank switches S4 and S5 in their OFF positions
(AUX switches are located on top edge of unit - see Figure 5 on page 16) if the
UPAM exhibits any of the following symptoms during station mode operation.
Symptoms
1.
UPAM disconnects from the line immediately after answering.
2.
UPAM answers and remains connected to the line but the page audio does not come
through the paging system. This condition is verified if the UPAM external contact
closures are still open during a page.