Specific Instructions
Trunk Port Connections - Ground Start
NOTE: Controls for VOX DELAY, PAGING TIME, MODE Switch S5 and AUX switches
S1, S2, S3, and S5 are not operable in this mode.
Procedure
1. Mount and ground the UPAM as described in General Instructions (pages 7 - 8).
2. Set MODE switches S1 and S2 to OFF position for use with the 48-volt power
supply (or ON position if a 24-volt supply is used).
3. Set MODE switch S3 to ON position and S4 to OFF position.
NOTE: Only pre-announce tone is available for ground start trunk applications.
4. Set AUX switch S4 to ON position (located on top edge of unit - see Figure 5 on
page 16).
5. Connect a jumper wire between N.O. and T terminals on UPAM.
6. Connect "Tip" of trunk port to COM terminal on UPAM.
7. Connect "Ring" of trunk port to R terminal on UPAM.
8. Connect PT and PR terminals on UPAM to the paging system, as shown in Section
3. Connect the N.O. and COM terminals to the control pair of the amplifier, if
required. Also, connect any background music source to the BGM IN jack on the
UPAM.