Installing the HSSI Net Module in a System 5000 Platform
B-2 117407-A Rev. A
The power drawn from the host chassis combined with that required for any other
net modules and accessories must not exceed the power rating of the host chassis.
You must install the net modules so as not to impair the integrity of the network
protection from hazardous voltages used or generated internally by the host
chassis.
Clearance and Creepage Distances
You must maintain the clearance and creepage distances (shown as X and Y,
respectively, in T
able B-2 and Figure B-1) between the HSSI net module and the
following:
• The host chassis in which it is installed
• Any adjacent net modules installed in the host chassis
The exception to this rule is the edge connector, which is located on the host
chassis backplane, where no minimum distance applies.
The creepage distances apply to a typical office environment. If the host chassis is
exposed to conductive pollution or dry nonconductive pollution that could become
conductive due to condensation, the creepage distances shown in parentheses in
T
able B-2 apply.
Table B-2. HSSI Net Module Clearance and Creepage Distances
Clearance (X) Creepage (Y)
Voltage Used or Generated by Other
Parts of the Host or Expansion Card
2.0 mm 2.4 (3.8) mm Up to 50 V rms or VDC
2.6 mm 3.0 (4.8) mm Up to 125 V rms or VCC
4.0 mm 5.0 (8.0) mm Up to 250 V rms or VDC
4.0 mm 6.4 (10.0) mm Up to 300 V rms or VDC