10-30 Troubleshooting the Data Module
Troubleshooting
Using a Terminal Emulator 10
If you cannot connect BCMS Vu Server to the DEFINITY system it may be
because BCMS Vu Server is not communicating with the data module. You
can check the communication between the PC and the data module by
using a terminal emulator that can establish a serial connection, such as
HyperTerminal™, a terminal emulator supplied with Windows.
Opening
HyperTerminal
and Setting Options 10
1. In the Start menu, select Programs/Accessories.
For Windows 95 only:
a. In the “Accessories” drop-down menu select HyperTerminal.
The “HyperTerminal” dialog box appears.
b. In the “HyperTerminal” dialog box, select “Hypertrm(.exe).”
c. Select OK.