308659-14.10 Rev 01
E-1
Appendix E
Syntax for Module Location
Table E-1 lists the syntax for specifying the physical location of a module for each
Nortel Networks device that the BCC supports.
Table E-1. Syntax for Specifying Module Location per Device
Platform Syntax
AN/ANH
<interface> <slot> <connector>
<interface>
= interface type: ethernet, token-ring, serial, etc.
<slot>
= 1 (AN/ANH is a one-slot device.)
<connector>
numbering starts with connector 1.
Example:
ethernet slot 1 connector 3
This is an Ethernet interface configured on AN/ANH connector 3, which exists on an
Ethernet adapter module. (Connectors 1 and 2 are on the base module.)
ASN
<interface> <slot> <module> <connector>
<interface>
= interface type: ethernet, token-ring, serial, etc.
<slot_number>
= 1, 2, 3, or 4, depending on the setting of the module ID switch on
each ASN.
<module>
numbering corresponds to net module numbering (1 through 4) on each
ASN.
<connector>
numbering starts at 1 on each net module (per media type).
Example:
ethernet slot 2 module 3 connector 2
This is an Ethernet interface on connector 2 of net module 3, in ASN 2 of a stacked ASN
configuration.