Using Source Routing Bridge Services
114060 Rev. A 2-29
Figure 2-15. SR Interface List Window
Parameter: Source Routing Ring Number
Default: 0x0
Range: 0x001 to 0xfff
Function: Identifies the ring number (ring ID) of this source routing circuit.
Instructions: Assign a ring number (ring ID) to this source routing circuit that is unique
among any other ring IDs, group LAN IDs, or internal LAN IDs in the
network.
You cannot use the value 0x0 that appears initially in the parameter box.
You must specify a value for this parameter that is within the given range.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.1.2.2.1.6