Customizing Signaling
308612-14.00 Rev 00
4-19
connect-tx-timer T313 4 1 to 24 Specifies the Connect Sent timer value (in
seconds). This timer begins when the circuit sends
a CONNECT message to the network.
The Connect Sent timer stops when the circuit
receives a CONNECT ACKNOWLEDGE message
from the network (indicating the completion of the
ATM connection for that interface).
If the timer expires before the circuit receives a
CONNECT ACKNOWLEDGE message, the circuit
clears the connection.
restart-request-tx-
interface-timer
T316 120 1 to 720 Specifies the Restart Request Sent on Interface
timer value (in seconds). This timer begins when
the circuit sends a RESTART message to the
network. The circuit uses the RESTART message to
return all VCs on the interface to the idle condition.
The Restart Request Sent on Interface timer stops
when the circuit receives a RESTART
ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a
RESTART ACKNOWLEDGE message, the circuit
can retransmit the RESTART message (see
Setting the Number of Allowable Restart
Messages” on page 4-25). If the circuit still does not
receive a response, the circuit enters the null state
until the appropriate maintenance action is taken.
(continued)
Table 4-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description