Customizing Signaling
117374-B Rev. 00
4-21
Using the BCC
To change a timer value, navigate to the signaling timers prompt (for example,
box; atm/11/1; signaling/11/1; timers/11/1) and enter:
timer-name
integer
timer-name
is the BCC name for the timer (see Table 4-1 for the names and
descriptions of signaling timers).
integer is the time value (in seconds) that you want the timer to use.
For example, the following command changes the disconnect timer to 8 seconds:
timers/11/1# disconnect-timer 8
timers/11/1#
Using Site Manager
To change a signaling timer value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling Attributes
. The ATM Signaling Parameters window
opens.
3. Set one or more of the following timers:
•T303
•T308
•T309
•T310
•T313
•T316
• T316c
•T322
•TDisc
•T398
•T399
Click on
Help
or see the parameter
descriptions beginning on page A-38.
(continued)