Strona 1 - System Start Up

BCM50 Rls 6.0 System Start Up Task Based Guide

Strona 2 - All Rights Reserved

BCM50 System Start Up 10 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Obtaining a Keycode File Keycodes unlock features and applications on the BCM.

Strona 3

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 11 PC Configuration The BCM50 has a dedicated OAM port. It is recommended that you perfo

Strona 4 - Table of Contents

BCM50 System Start Up 12 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Physical Connection to the BCM The BCM50 OAM port can accommodate either a patch cable

Strona 5

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 13 3. Type ping followed by the default IP Address of the LAN port you are connected t

Strona 6

BCM50 System Start Up 14 NN40010-318 Issue 1.2 BCM50 Rls 6.0 1. Point your web browser at the BCM’s IP Address. 2. You may get presented with

Strona 7 - LAN Connection

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 15 4. You may be presented with a second certificate error message. To avoid seeing the

Strona 8 - WAN Connection

BCM50 System Start Up 16 NN40010-318 Issue 1.2 BCM50 Rls 6.0 6. You will be asked to enter the BCM account credentials. Tick the Save Credentials

Strona 9 - Flow Chart

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 17 8. From the list of Applications, select Business Element Manager and click on the R

Strona 10 - Obtaining a Keycode File

BCM50 System Start Up 18 NN40010-318 Issue 1.2 BCM50 Rls 6.0 11. If there hasn’t been a previous installation of Element Manager an “empty” version

Strona 11 - PC Configuration

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 19 Element Manager Connection to the BCM To access Element Manager for configuration pur

Strona 12 - BCM50 System Start Up

BCM50 System Start Up 2 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Copyright © 2010 Avaya Inc. All Rights Reserved. Notices While reasonable efforts have

Strona 13

BCM50 System Start Up 20 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. You will be presented with the Element Manager interface. 4. Open the Network

Strona 14

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 21 6. A warning screen will appear, read the warning and click OK. 7. You will be p

Strona 15

BCM50 System Start Up 22 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Use the following procedure to load a Keycode file. 1. Access Element Manager (refer

Strona 16

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 23 5. The features will be applied and viewable in the Feature Licenses table

Strona 17

BCM50 System Start Up 24 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Configuring the LAN IP Address If the IP Address of the BCM system requires c

Strona 18

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 25 3. Click on the LAN Interfaces tab. Select the Customer LAN row, and click Modify in

Strona 19

BCM50 System Start Up 26 NN40010-318 Issue 1.2 BCM50 Rls 6.0 5. If you enter an IP Address manually, you will see the following WARNING

Strona 20

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 27 10. If the BCM is obtaining its network settings via DHCP (either its own DHCP server

Strona 21 - Software Keycodes

BCM50 System Start Up 28 NN40010-318 Issue 1.2 BCM50 Rls 6.0 11. DNS settings can also be entered, if you are not receiving this informa

Strona 22

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 29 1. From the Configuration tab, open the Data Services folder, and select DH

Strona 23

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 3 Downloading documents For the most current versions of documentation, see the Avaya Su

Strona 24

BCM50 System Start Up 30 NN40010-318 Issue 1.2 BCM50 Rls 6.0 5. Click on the Add button. Enter the following settings and click OK:  From IP Add

Strona 25

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 31 Attribute Value Description node is used only as a last resort. Default: H-node L

Strona 26

BCM50 System Start Up 32 NN40010-318 Issue 1.2 BCM50 Rls 6.0 5. A Progress Update window will appear. Setting the Date and Time 1. From the Co

Strona 27

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 33 4. If setting the Date and Time Source as NTP, click on the Modify butto

Strona 28 - Configuring DHCP

BCM50 System Start Up 34 NN40010-318 Issue 1.2 BCM50 Rls 6.0 7. Also ensure that the correct Time Zone is selected. Date & Time Settings At

Strona 29

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 35 3. Click Cold Reset Telephony Services. 4. The Cold Reset Telephony dialog

Strona 30

BCM50 System Start Up 36 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Initialising CallPilot Manager Use the following procedure to initialise the CallPilot

Strona 31 - Setting the System Name

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 37 4. The Quick Install Wizard form displays. If your VoiceMail system is already

Strona 32 - Setting the Date and Time

BCM50 System Start Up 38 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Attribute Description From Line Enter the line number of the first line in the range

Strona 33

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 39 2. You can now proceed with configuring the Media Bay Module type. Trunk Media Bay

Strona 34 - Attribute

BCM50 System Start Up 4 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Table of Contents System Start Up ...

Strona 35

BCM50 System Start Up 40 NN40010-318 Issue 1.2 BCM50 Rls 6.0 2. In this example the system has a single PRI Digital Trunk Media Bay Module install

Strona 36

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 41 should be no Secondary reference defined on any DTM/BRI. Note that there should only

Strona 37

BCM50 System Start Up 42 NN40010-318 Issue 1.2 BCM50 Rls 6.0 4. As a general rule for Trunk modules (PRI, BRI, DASS2 etc.) you may wish to check t

Strona 38 - Media Bay Modules

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 43 PRI Module-Specific Settings Attribute Value Module/line type Trunk type All

Strona 39 - PRI Modules

BCM50 System Start Up 44 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Attribute Value Module/line type Appears only for NI protocol. Protocol type User

Strona 40

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 45 Attribute Value Module/line type Number Length This number allows the system t

Strona 41

BCM50 System Start Up 46 NN40010-318 Issue 1.2 BCM50 Rls 6.0 DASS2 Modules 1. Double click in the Configured Device field and set it to

Strona 42

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 47 DASS2 Module-Specific Settings Attribute Value Module / Line Type Clock Source Pr

Strona 43

BCM50 System Start Up 48 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Trunk Port Details tab Port details 3. Both trunk and analog station modules show

Strona 44

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 49 Attribute Value Module type Indicates auxiliary items added to the telephony de

Strona 45

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 5 Registering IP Terminals ...

Strona 46 - DASS2 Modules

BCM50 System Start Up 50 NN40010-318 Issue 1.2 BCM50 Rls 6.0 DPNSS Modules 1. Double click in the Configured Device field and set to DTM - DPNSS

Strona 47

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 51 DPNSS Module-Specific Settings Attribute Value Description Clock Source Primary

Strona 48

BCM50 System Start Up 52 NN40010-318 Issue 1.2 BCM50 Rls 6.0 4. Open the Provision Lines tab and check that the required lines are provisioned by

Strona 49

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 53 6. The module should be Enabled once configured. BRI Module 1. Double click i

Strona 50 - DPNSS Modules

BCM50 System Start Up 54 NN40010-318 Issue 1.2 BCM50 Rls 6.0 2. View the Provision Loops tab and check that the required lines are provisioned by

Strona 51 - Description

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 55 3. Select the Loop Type from the option box provided. 4. Configure the loops and

Strona 52

BCM50 System Start Up 56 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Attribute Value Description Attribute Value Description Clock source Primary

Strona 53 - BRI Module

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 57 2. Then select Expansion 1.1 and configure the Disconnect timer settings as require

Strona 54

BCM50 System Start Up 58 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. Once configured the bus should be Enabled (for the 8-port version, it will be nece

Strona 55

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 59 DSM 16/32 Modules 1. Double click in the Configured Device field and from the drop

Strona 56

BCM50 System Start Up 6 NN40010-318 Issue 1.2 BCM50 Rls 6.0 System Start Up Overview This guide details the steps required to set the BCM to a basi

Strona 57

BCM50 System Start Up 60 NN40010-318 Issue 1.2 BCM50 Rls 6.0 2. Both trunk and analog modules show port details. Ports settings are directly rela

Strona 58 - Station Media Bay Modules

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 61 3. The bus (or both busses) should now be Enabled. Note: For the DSM32 MBM both E

Strona 59 - DSM 16/32 Modules

BCM50 System Start Up 62 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. The bus should now be Enabled. Combination Modules These modules provide a c

Strona 60

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 63 Combination Module Configuration 1. Double click in the Configured Device fie

Strona 61

BCM50 System Start Up 64 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. Then select Expansion 1.2 (or Expansion 1.3 if the 8 x 16 MBM has been selected) w

Strona 62 - Combination Modules

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 65 Connecting the BCM to the Network NOTE: If the BCM is in a Standalone Install

Strona 63

BCM50 System Start Up 66 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. Select IP Sets from the Configured Device column. The Details for Module displays

Strona 64

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 67 Additional Information Startup Profile Configuration Tool It is possible to apply In

Strona 65 - Registering IP Terminals

BCM50 System Start Up 68 NN40010-318 Issue 1.2 BCM50 Rls 6.0 3. Click the Macro Security button. 4. Select Medium or Low. 5. Click OK (twice)

Strona 66

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 69 Obtaining the Startup Profile Configuration Tool The Startup Profile Configuration

Strona 67 - Additional Information

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 7  DHCP On/Off?  License File (Keycode File)  Telephony Template  Start DN of t

Strona 68

BCM50 System Start Up 70 NN40010-318 Issue 1.2 BCM50 Rls 6.0 4. Accept any further security messages that you may get presented with. 5. You

Strona 69

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 71 7. From the Applications list, select Other Administrator Applications and click Run

Strona 70

BCM50 System Start Up 72 NN40010-318 Issue 1.2 BCM50 Rls 6.0 11. Select the Save button from the File Download window and save the Profile template

Strona 71

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 73 13. The excel file will open from that location. You may wish to view the Usage Instr

Strona 72

BCM50 System Start Up 74 NN40010-318 Issue 1.2 BCM50 Rls 6.0 14. Once you have read the instructions select the Startup Profile Template w

Strona 73

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 75 DHCP Server If Server is set to Enabled, you can specify the Default Gatew

Strona 74 - Startup Profile Settings

BCM50 System Start Up 76 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Other Settings It is recommended that the rest of the settings in the Start

Strona 75

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 77 18. If using a Keycode file, ensure you type in the name of the file correctly (e.g.

Strona 76

BCM50 System Start Up 78 NN40010-318 Issue 1.2 BCM50 Rls 6.0 19. Once you have entered the configuration details as outlined in the follo

Strona 77

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 79 21. Save a version of the Startup Profile (.sps file) on the USB memory stick. This

Strona 78

BCM50 System Start Up 8 NN40010-318 Issue 1.2 BCM50 Rls 6.0 WAN Connection This scenario only relates to a BCM50(b)e installation. The WAN informa

Strona 79 - Running the Startup Profile

BCM50 System Start Up 80 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Next Step When the Startup Profile has been applied, you should continue wit

Strona 80 - Keycode Credit System

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 81 The BCM installer’s responsibilities can be summarized as follows: 1. Apply the

Strona 81

BCM50 System Start Up 82 NN40010-318 Issue 1.2 BCM50 Rls 6.0 Avaya Documentation Links  Installation and Maintenance Guide  BCM50 Installation

Strona 82 - Avaya Documentation Links

BCM50 System Start Up NN40010-318 Issue 1.2 BCM50 Rls 6.0 9 Flow Chart The flow chart outlines the steps involved in System Start-Up: