Configuring Line Services
A-46 114078 Rev. A
Parameter: Setup Alarm Threshold (seconds)
Path: MCE1 Connector > Edit Logical Lines > Port Details > MCE1 Port Parameters
Default: 2 seconds
Options: 2 to 10 seconds
Function: Specifies the time interval during which MCE1 tolerates a performance defect
or anomaly. If the performance defect or anomaly is still present when this time
interval expires, MCE1 records a performance failure and logs an event
message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.7
Parameter: Clear Alarm Threshold (seconds)
Path: MCE1 Connector > Edit Logical Lines > Port Details > MCE1 Port Parameters
Default: 2 seconds
Options: 2 to 10 seconds
Function: Specifies the clear time for performance failure conditions. If the defect or
anomaly clears within this time interval, MCE1 records a performance-cleared
condition and logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.8
Parameter: International Bit
Path: MCE1 Connector > Edit Logical Lines > Port Details > MCE1 Port Parameters
Default: Disable
Options: Enable
| Disable
Function: Specifies whether the international bit should be set in the E1 frame.
Instructions: Select Enable to set the international bit, or select Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.16