BayRS, BCC, and Site Manager Software Version 15.0.0.0 Fixed Anomalies
8
308681-15.0 Rev 00
CR 138234-2: DLSw
In a hub and spoke configuration with V2 DLSw, the routers hub DLSw slot
eventually runs out of GIDs and resets.
CR 138659-1: Technician Interface
Running the
show sws pap
script does not produce the proper output.
CR 138872-1: NetBIOS over IP
In a multinetted environment where two routers are connected to the same LAN
and enabled to route NetBIOS over IP on each of their configured addresses, a
routed packets time to live (TTL) value can never reduce to zero. As a result, a
directed broadcast coming from one subnet that is then routed into the other is
never discarded.
CR 139111-1: APPN
The log file shows assertion errors in the APPN subsystems when the router is
under load.
CR 139115-2: PIM
Certain products of vendors outside of Nortel are not completely RFC compliant
regarding PIM. Work-arounds were incorporated into BayRs to allow connectivity
to these products.
CR 139158-1: Quad 100 BT/Gigabit
In a DLSw configuration, the router corrupts outbound SNA frames on a quad
100BT or gigabit module if the IP upstream link to the DLSw peer is made over
ATM/PVC with LLC/SNAP encapsulation.
CR 139337-2: WCP
When you use hi_fn compression on a DoD circuit between the Nautica Clam
router and an AN router, file transfer is interrupted with an Incorrect Sequence
Number error.