Chapter 2 Fault Management System 225
Business Communications Manager - Management User Guide
Event ID: 330 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
loss of frame. The module is in a no-new-calls state. DTCM = %1.
Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 330, Sev=P5, Cat=C
Event ID: 331 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
controlled slip overflow. The module is in a no-new-calls state. DTCM
= %1.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 331, Sev=P5, Cat=C
Event ID: 332 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
remote alarm indication. The module is in a no-new-calls state. DTCM
= %1. Intervention is required to find out why the Digital Trunk
Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 332, Sev=P5, Cat=C
Event ID: 333 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
loss of frame in timeslot 16. The module is in a no-new-calls state.
DTCM = %1. Intervention is required to find out why the Digital Trunk
Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 333, Sev=P5, Cat=C
Event ID: 334 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
alarm indication signal in time slot 16. The module is in a no-new-calls
state. DTCM = %1. Intervention is required to find out why the Digital
Trunk Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning